Specifications
Function : Measurement of AC leakage current, AC current and on-line AC current
Power : DC3V Button-type battery
Test Mode : Clip-on CT, integral mode
Display Mode : Four Bits LCD display
Dimensions : 64mm 160mm 23mm
LCD Dimensions : 35mm 21.5mm; display domain: 32mm 15mm
Clamp Mouth : 40mm
Sampling Rate : about 2 times/s
Range : 0.00mA~300.0A (50/60Hz)
Resolution : 0.01mA
Measuring range : 30mA / 300mA, 30A / 300A, second-range manual switch, Automatic switch in all ranges
Measurement accuracy :
0.00mA~9.99mA: 1.2% 5dgt
10.0mA~300.0mA: 1.5% 5dgt
0.00A~9.99A: 1.2% 5dgt
10.0A~99.9A: 1.5% 5dgt
100.0A~199.9A: 2% 5dgt
200.0A~300.0A: 4% 5dgt
Line voltage : Line test under AC600V
Data Storage : 60 groups, FU symbol flickering means storage is full
Peak Holding : Peak value capture and holding function, press HOLD button continually to show peak value in the course of testing.
Data Holding : Data holding function:displayed by DH symbol
Overflow display : Outrange overflow display:displayed by OL symbol
Automatic shutdown : After starting up the leaker for 5 minutes, it will shut down automatically to reduce battery consumption.
Battery voltage : When battery voltage reduced to 2.5V~2.7V, battery low voltage symbol will filker to remind replacing battery; at this time, measurement accuracy will decrease.
Leaker Quality : About 120 g (with battery)
Rating Power : about 5mW
Working temperature and humidity : -0~40; below 80%rh
Storage temperature and humidity : -10~60;below 70%rh
Insulation strength : AC2kV/rms (between core and box)
Applicable safety rules : IEC1010-1 IEC1010-2-032 pollution, etc 2 CATIII (600V)
Power : DC3V Button-type battery
Test Mode : Clip-on CT, integral mode
Display Mode : Four Bits LCD display
Dimensions : 64mm 160mm 23mm
LCD Dimensions : 35mm 21.5mm; display domain: 32mm 15mm
Clamp Mouth : 40mm
Sampling Rate : about 2 times/s
Range : 0.00mA~300.0A (50/60Hz)
Resolution : 0.01mA
Measuring range : 30mA / 300mA, 30A / 300A, second-range manual switch, Automatic switch in all ranges
Measurement accuracy :
0.00mA~9.99mA: 1.2% 5dgt
10.0mA~300.0mA: 1.5% 5dgt
0.00A~9.99A: 1.2% 5dgt
10.0A~99.9A: 1.5% 5dgt
100.0A~199.9A: 2% 5dgt
200.0A~300.0A: 4% 5dgt
Line voltage : Line test under AC600V
Data Storage : 60 groups, FU symbol flickering means storage is full
Peak Holding : Peak value capture and holding function, press HOLD button continually to show peak value in the course of testing.
Data Holding : Data holding function:displayed by DH symbol
Overflow display : Outrange overflow display:displayed by OL symbol
Automatic shutdown : After starting up the leaker for 5 minutes, it will shut down automatically to reduce battery consumption.
Battery voltage : When battery voltage reduced to 2.5V~2.7V, battery low voltage symbol will filker to remind replacing battery; at this time, measurement accuracy will decrease.
Leaker Quality : About 120 g (with battery)
Rating Power : about 5mW
Working temperature and humidity : -0~40; below 80%rh
Storage temperature and humidity : -10~60;below 70%rh
Insulation strength : AC2kV/rms (between core and box)
Applicable safety rules : IEC1010-1 IEC1010-2-032 pollution, etc 2 CATIII (600V)